ELECTRICAL CONNECTIONS
Electrical Installation
MAIN BREAKER PANEL
LINE 1
N
LINE 2
OPTION 2
MAIN BREAKER PANEL
OPTION 3
20-60AMP HARDWIRED
Option 2 shows the power from GFCI breaker installed into main service panel to a
service disconnect within line-of-site of the spa. If the manufacturer of your homes main
breaker panel makes a GFCI breaker, you may be able to add it to an open slot in the
panel.
Option 3 shows the power from main service panel to a GFCI subpanel within line-of-site
of the spa.
(Note: Most local codes will allow a GFCI subpanel to be a disconnect. If this is
not the case in your installation, a disconnect must be provided.)
REFER TO GFCI WIRING DETAIL ON
PAGE 8
GFCI Installed in Main Service Panel
Subpanel GFCI Installed
PORTABLE SPA
7
INLINE SPA DISCONNECT
20-60AMP HARDWIRED
GFCI DISCONNECT
LINE 1
N
LINE 2
INLINE SPA DISCONNECT
INLINE SPA DISCONNECT
TO PORTABLE SPA
REFER TO GFCI WIRING DETAIL ON PAGE 8