A
amplitude of
the oscillation and corresponds to the Volt value as a percentage of the maximum out-
put voltage.
O
Offset
between zero and the baseline of the oscillation and corresponds to the Volt value as a per-
centage of the maximum output voltage.
F
Frequency of
the oscillation - is given as a multiple of 10 mHz
Area
Value range
A
10%...100%
O
10%...100%
A+O
max. 100
F
0.01Hz...
2Hz...
A minimum offset of 10% is specified in this operating mode. The amplitude of the sine is added to the offset.
The value of 100% is not exceeded, nor is the value falling below 0%.
Make sure that the sum of
amplitude
and
offset
is less than 100%.
A negative amplitude cannot be displayed.
Highlight the setting values of the curve, press and
enter the desired value and confirm with
.
Save and exit the setting with F5 .
Setting QL326 Sensors
When using the load valve for the first time, the connected sensors are still unknown. The temperature sensor is
always set
INACTIVE.
If a temperature sensor is used, it is useful to activate it before scanning the CAN bus.
Proceed as follows:
1
Use
to highlight
Temperatur sensor
and press .
2
Use
to highlight
Temperature sensor
and confirm with to
YES
.
3
Leave the setting with F5 .
It is also possible to add a temperature sensor at a later date. For this purpose the CAN bus can be scanned
with F1 . The found sensor will be entered automatically.
Scan CAN bus
Scan the CAN bus for connected sensors of the load valve.