Technical data
Mechanical data
Material housing
3.4365
... turbine wheel
1.0718
... Seals
FKM
Mechanical connection
ISO 228 - G 1¼"
Mounting position
any
Weight
approx. 6,5 kg
Medium temperature
max. 120 °C
Ambient / storage temperature
-20...+65 °C
Hydraulic data
Permissible operating pressure 420 bar
Measuring range
16...600 l/min
Calibration viscosity
30 mm²/s (cSt)
Viscosity range
1...100 mm²/s (cSt)
Recommended filter
10 µm
Electrical data of the sensors
Output signal
CAN 2.0A
Electrical measuring connection
M12x1 5-pin plug
Protection class
IP 40 (EN 60529 / IEC 529)
Supply voltage Ub
12...24 VDC
Power consumption
max. 1 A
Overvoltage protection
36 VDC
Response time
≤ 50 ms
Electrical data of the control box
Input signal
CAN 2.0A
Control signal to proportional
valve
0...10V (
1
)
Connection Input/Output
M12x1 5-pin socket and plug
Connection Supply voltage
M16x0,75 3-pin connector
Supply voltage Ub
12...24 VDC
Power consumption
max. 1 A
Measurement accuracy
Flow rate
±0.5% of MW @ 30mm²/s (cSt)
Pressure
typ. ±0.5% of MW (
2
)
Temperature
typ. ±2°K (2)
(
1
) When used in the CAN bus, this range corresponds to the default value 0...100% (0…10V).
(
2
) Detailed information on the measuring accuracy of the individual sensors can be found in the corresponding
product data sheets.