background image

Sensor Faucets and Flush Valves

OPERATION & MAINTENANCE MANUAL

6300-LR Series Faucet

5055 Forsyth Commerce Rd, Ste 124, Orlando, FL 32807

Phone (800) 922-9883 | Fax (866) 670-5580

www.hydrotekintl.com

Summary of Contents for H-6300-LR

Page 1: ...Sensor Faucets and Flush Valves OPERATION MAINTENANCE MANUAL 6300 LR Series Faucet 5055 Forsyth Commerce Rd Ste 124 Orlando FL 32807 Phone 800 922 9883 Fax 866 670 5580 www hydrotekintl com ...

Page 2: ...vailable in 9 H 6300 LR Low Lead AC Powered 9 HE 6300 LR Low Lead Battery Powered with Enduratek Features Vandal resistant faucet body with chrome plated solid brass construction Faucet design allows quick above the deck access to all major faucet component parts 30 second time out feature prevents accidental sink overflow Above the deck external or internal temperature adjustment variation Standa...

Page 3: ...nal Multi Unit Adapter Serves up to 6 faucets UL CSA Input AC 120V Output DC 7 5V 3A Battery Mode with Enduratek Battery Powered Models 4 AA Alkaline Batteries Battery Service Life 1 5 million on off cycles Up to 10 years Warranty 3 years Package Includes 1 Faucet with sensor solenoid 1 3 Gooseneck spout 1 Armored S S supply tube with filter 1 Mounting hardware 1 1 5 GPM Laminar Flow Control 1 7 5...

Page 4: ......

Page 5: ...tronic PCB Sensor is defective No light no clicking Reinsert batteries Reattach power adapter Replace electronic PCB Solenoid valve is clogged Solenoid is clicking but no water is coming out Clean solenoid In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no...

Page 6: ... Valve and reas semble the faucet in reverse order CONTROL MODULE P C BOARD REPLACEMENT 1 Disconnect power by disconnecting the AC adapter or battery pack underneath the faucet 2 Unscrew the Body Set Screws and with an upward motion pull the the upper faucet body off of the faucet base 3 Disconnect the connector for the Pressure Release Valve Assembly 4 Unscrew the Retaining Rods and pull them up ...

Page 7: ...eck Spout Assembly H41 001 2 1 5 GPM Laminar Flow Control HB 003EF 3 Pressure Valve Assembly H41 004 4 Sensor PCB H41 005 5 Battery Holder H41 007 6 Supply Tube HB7 027 7 In Line Filter H63 007 Please visit our website www hydrotekintl com for our most current Products Pricing Sheet 1 2 3 4 5 6 7 ...