Page 56
Risk of electrical shock!
Hazardous electrical high voltage!
Follow safety instructions for work on live equipment.
»
Switch on unit and monitor for leakage during 15-30
minutes of operating.
»
In case of leakage switch of unit and redeem lea-
kage(s).
»
Monitor again; repeat procedure until no more leakages
are detected.
Risk of electrical shock!
Personal safety by proper grounding may not be ensured.
In order for the unit cover to be safely grounded, the cover must
be fully closed and the lock must be engaged (this refers only to
humidifier types HyLine and MiniSteam).
Check for leakages
Close cabinet