Page 57
9.4 Electrode wear
Electrode wear depends on:
•
feed water composition and conductivity
•
the quantity of steam produced
Monitor electrode lengths!
When the electrodes are less than 1/3 to 1/2 of their original
length, they should be replaced . At the latest, the replacement
should be carried out when a maintenance message is dis-
played asking for replacement. This maintenance message will
appear after one hour of operation at maximum water level. The
humidifier operation will then stop.
9.4.1 Original Electrode Lengths
Original lengths of HygroMatik large area stainless-steel elec-
trodes are:
HyLine:
CompactLine:
Type
HY05-HY08 HY13-HY60 HY90-HY116
Length [mm]
[inch]
155
6.1
235
9.25
300
11.8
Type
C01 C02 C06 C10 C17- 45 C58
Length [mm]
[inch]
115
4.5
80
3.2
125
4.9
155
6.1
235
9.25
300
11.8