Page 59
The numbers in paranthesis refer to the exploded view figure.
»
Remove and open cylinder, as described in Section 8.3
"Removing and Cleaning Steam Cylinder."
»
Loosen knurled nuts (5) and remove electrodes (48).
»
Install new electrodes and hand tighten the nuts.
»
Use solvent-free, HygroMatik-quality o-rings (for flange,
cylinder base and steam hose adapter).
»
Assemble steam cylinder and place it into cylinder.
»
Connect plugs (4) directly to the electrodes (48) (with
gray, red and black knurled nuts). It is not necessary to
detach the knurled nuts!
Ensure proper plug seating on electrodes!
The plugs must be pressed down onto the electrodes as far as
they will go.
Connect plugs to the corresponding electrodes as indicated by
the color of the knurled nut.
»
Attach plug (8) to the sensor electrode. (Knurled nut (9)
- gray).
»
Switch breaker back on.
»
Switch on the unit and check for leaks after 15-30 min-
utes of operation.
If leakage occurs, switch off power supply and follow safety
instructions for work on live components.
Water conductivity is too high or water is not decanted oftenly
enough if the following phenomina are observed:
•
electrodes must be frequently replaced,
•
black slime collects inside the cylinder, or
•
there is "lightning" in the cylinder.
In all of these cases please contact your expert dealer.
Please note
Please note