Seite 22
6. Mechanical installation
Risk of foot injuries!
Prevent unit from dropping during installation!
Helping hand of a second person is advisa-
ble.
Risk of electrical shock!
Hazardous electrical voltage.
During installation, the unit must be discon-
nected from power supply and secured
against being switched on again. The
absence of voltage must be ensured by a
measurement.
6.1 Environment Parameters to
be met and Mounting Recom-
mendations
When selecting the installation site for the
HPS unit, take the following into account:
•
Protection class IP20
•
By design, HygroMatik steam humidifi-
ers are not qualified for outdoor instal-
lation (electronical components and
water-bearing parts may be damaged)
•
Ambient temperature must lie between
+5 and +40 °C (+41 and +104 °F) in
order to protect the unit electronics
against damage; frost may damage the
steam cylinder, the solenoid valve and
pump, as well as make hoses burst
•
Relative humidity must not exceed
80 % r.h., since values beyond may
lead to electronic malfunction or dam-
age
•
Installation in a closed room requires
aeration and, eventually, temperature
conditioning in order to meet the a.m.
environmental conditions
•
Make use of existing water connections
for supply and draining
•
The on-site waste water connection
must be a free outlet according to DIN
EN 1717.
•
The installation room must be properly
ventilated and equipped with a floor
drain. Alternatively, a water stop device
(e.g. leakage detector) can be used.
•
Use genuine spare parts only
•
After any repair work, have qualified
personnel check the safe operation of
the unit
•
Attaching or installing of
additional
components
is permitted only with the
written consent
of the manufacturer
The high-pressure nozzle system is IP20 pro-
tected. Make sure that the unit is not object to
dripping water in the mounting location.
Wall distance
During installation, the wall distances indi-
cated in the sketch below must be observed:
WARNING
!
WARNING
!
NOTICE
(
>500/19.7
>200/7.8
>300/11.8
>200/7,8
dimensions in
mm/inch