5.3 Requirements on the installation site of the
WaterLine softener device
•
The floor must be even and dry and have a load capacity
that reflects the operating weight of the softener device as
given in the technical specifications. An even floor is man-
datory in order to allow for a tensionless arranging of the
tubing for the device
•
The WaterLine softener device must be levelled on-site.
For securing the system against tilting by inadvertant
impacting, a wall mounting set is available as an option
(Article no. B-5000105)
•
The floor must be clean and free of pointed objects,
stones, construction waste etc. in order not to pose any
damaging hazard to the brine tank.
•
If required set-up a fundament
•
A sewer junction must be in close proximity
•
For safety reasons the installation location should feature
a floor gully. If no gully exists, a water stop may alterna-
tively be used.
5.4 Set-up of the WaterLine pendulum devices
WL-D/DP
The HygroMatik softener devices WL-D and W-DP are only par-
tially preconfigured when delivered. For transportation safety
reasons the second pressure tank is separatly packed. Before
operating the system, the tubing between the corresponding
connections on the control valve on top of the one pressure tank
and the connecting head on the other pressure tank must be put
in place. The connecting tube coupling nuts must only be
secured hand-tight.
5.5 Attaching the tubing for raw water and soft
water
5.5.1 Prerequisites for the correct connection of the
tubing on the softener device
•
Raw water flow pressure must be 2.5 bar minimum. If not
the case, proper functioning of the WaterLine softener
device may be impaired by air cushions that may built up.
For monitoring flow pressure, it makes sense to integrate a
manometer into to the raw water pipe, if not already pre-
sent.
•
Any installations (such as elbows etc.) upstream of the sof-
tener device that may reduce flow pressure are not allo-
wable
•
Max. flow pressure must never exceed 7.0 bar. If a pres-
sure situation, pressure peaks or hydraulic shocks beyond
7.0 bar may be encountered, a pressure reducer must be
implemented upstream of the softener device.
Securing the WaterLine softener
device by means of the optionally
Tension belt
availabe wall attachment set
Bracket
Tubing of WL-D/DP