Page 22
»
Insert waste water hose into waste water elbow on con-
trol valve and screw-on connecting nut hand-tight
»
Attach waste water hose with free outlet in order to pre-
vent microbial contamination hazard
»
lay hose without cross-section reduction or kinks
The optionally available waste water connection set (article no.
E-5000040) may be used for connection.
Please note:
Hazard of backflow! Make sure that the waste
water sees a permanent decline when routed to the drain. In
case of a drain situated higher then the control valve the use of a
backflow flap is a must.
5.8 Connecting the brine tank overflow
A brine tank overflow hose is not provided with the WaterLine
softener device. A proper hose must be provided by the cus-
tomer. The hose provided for waste water draining may be cut in
two and the second hose piece may be used for overflow con-
nection.
As is the case with waste water, overflow also needs a free out-
let.