Page 31
Check salt tablet supply
A certain amount of salt must always be detectable in the brine
tank in order to ensure the availability of the 25 percent brine
required for the regeneration of the exchanger resin. The latest
instance for filling up the salt tablet supply is when the liquid
level exceeds the salt level.
Refill salt
It is recommended to refill salt tablets up to the lower rim of the
feed opening when the amount of salt consumed corresponds to
approx. one quart of the total tank volume.
Attention!
Make sure not to introduce any contamination into
the brine tank since this may impair water quality. When refilling
salt, hygienically flawless proceeding must always be ensured.
Please note.
For
hygienic
reasons the following precautionary
measures must be taken:
•
Store the regeneration salt exclusively in a dry and clean
place
•
Preferably, do not use open packages or bags
•
Clean the package or bag outside before opening it
•
Fill the brine tank only directly with salt from the package
or bag
•
Under all circumstances, close the brine tank carefully with
the cap provided for this purpose!
Please note:
In case of a regeneration cycle without the ade-
quate brine concentration (i.e. 25 percent), one more regenera-
tion cycle is required for single softener devices after the 6 hours
of wait time for the salt tablets to dissolve. Double softeners
require two regeneration cycles because of the two pressure
tanks.
Check operating pressure of the softener device
Flow pressure must lie within specified tolerance (see technical
specifications).