background image

 

 

 

Ref: HY.007b-version3

 -

 10/6/2020                            ©Analis/Hymetec                                                           

p

. 10/20 

 

 BOTTOM VIEW 

 

Figure 7 

 

Ref. 

Part 

Identification plate with  

CE mark 

Ventilation grid 

Power cord storage compartment 

Support stud (4 x) 

3.6

 

Accessories 

 

TRANSPORTATION BAG 

 

Figure 8 

 

HYSPRAY

 TROLLEY 

 

Figure 9 

The trolley is not included in the package. Please contact Analis or your distributor. 

B

C

A

D

D

Summary of Contents for Hyspray

Page 1: ...User Manual FR NL VERSIONS OF THIS MANUAL ARE AVAILABLE ON WWW DISINFECTION BE...

Page 2: ...ray 6 2 3 H2O2 related safety guidelines 7 3 About the Hyspray 8 3 1 Function 8 3 2 Intended use 8 3 3 Advantages 8 3 4 Kit content 8 3 5 Main components 9 3 6 Accessories 10 4 Working with the Hyspra...

Page 3: ...your Hyspray ORIENTATION CONVENTION Figure 1 shows the orientation convention Wherever you stand relative to the Hyspray the indications Front Back Right and Left are always as shown on Figure 1 Figur...

Page 4: ...ional information and support A video user s guide is also available on http www disinfection be or online on youtube For the overall procedure to disinfect a room with the Hyspray check the following...

Page 5: ...the power cord to move the Hyspray Keep the power cord clear of heat sources oil and sharp edges Inspect the power cord periodically and replace if damaged Disconnect the Hyspray from the mains when...

Page 6: ...room in the pre set time 90 600 sec Do not enter the area to be disinfected when the spraying procedure has started HANDLING OF THE CONSUMABLE HYPRO TECHNICAL 7 H2O2 Use safety gloves and safety gogg...

Page 7: ...se with a flammable and or non admitted product Do not inhale the substance Do not spray directly towards an object in the room SPRAYING MATERIAL UNDER PRESSURE Do not aim the nozzle at human beings o...

Page 8: ...ogen peroxide solution For more details refer to the technical data of HyPro technical This solution is available in 1L and 5L packaging Hyspray efficiently disinfects surfaces and non invasive medica...

Page 9: ...B Latch C Nozzle D Operating panel see details below E Flexible straw with filter OPERATING PANEL Figure 5 Ref Part A Display B Start Stop key C Down key decrease values D Up key increase values BACK...

Page 10: ...f Part A Identification plate with CE mark B Ventilation grid C Power cord storage compartment D Support stud 4 x 3 6 Accessories TRANSPORTATION BAG Figure 8 HYSPRAY TROLLEY Figure 9 The trolley is no...

Page 11: ...d adequate eye protection 4 1 Preparing the Hyspray for disinfection 1 Place the Hyspray on a stable surface possibly onto the Hyspray Trolley 2 Press the latch as shown below and take the nozzle out...

Page 12: ...e identification plate Figure 7 on p 10 corresponds to the local mains voltage before you connect the unit 2 Check that there is sufficient product in the HyPro Technical 7 bottle to complete the enti...

Page 13: ...tdown time elapses The display shows the elapsed countdown time If needed you can stop the countdown period by pressing the Start Stop button again Likewise you can start a new countdown by pressing t...

Page 14: ...verse order as in Preparing the Hyspray for disinfection on p 11 4 3 Emergency stop and restart 1 You can stop the Hyspray at any time by putting the ON OFF switch at the back of the unit in the OFF p...

Page 15: ...he jet of the nozzle is not clogged Check that the bottle is properly installed THE DISPLAY SHOWS The disinfection cycle was interrupted e g due to a power failure Press the Start Stop key during 3 se...

Page 16: ...Ref HY 007b version3 10 6 2020 Analis Hymetec p 16 20 5 4 Environmental disposal Check the ISO14000 guidelines and local regulations for scrapping disposal and recycling...

Page 17: ...apacity 500 A 125 V Type Schurter 0001 2515 IEC 60127 2 UL 248 14 8 A slowly acting Rated breaking capacity 1500 A 250 VAC Type ESKA 522 700 Room size for disinfection 5 m to 165 m 5 m to 165 m Disinf...

Page 18: ...Ref HY 007b version3 10 6 2020 Analis Hymetec p 18 20 6 3 Compliance EC DECLARATION OF CONFORMITY Figure 20...

Page 19: ...Ref HY 007b version3 10 6 2020 Analis Hymetec p 19 20 EMC Figure 21...

Page 20: ...N BE Head Office NAMUR Rue de N verl e 11 B 5020 NAMUR Belgium Tel 32 81 25 50 50 TVA BE 0430 744 435 BTW RPM Namur 0430 744 435 RPR Namen Branch Office GENT Bijenstraat 18 Entrance C B 9051 GENT Belg...