INSPECTION
CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, m e a s u r e the DC voltage
between the battery terminal
and
.
If the tester reads under 14.0 V or over 15.0 V, check
the magneto no-load performance and regulator /
rectifier.
MAGNETO NO-LOAD PERFORMANCE
Disconnect the three lead wires from the magneto
terminal.
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the AC voltage
between the three lead wires.
If the tester reads under 67 V or over 99 V the magneto
is faulty.
14.0
15.0 V (at 5,000 rpm)
Standard charge
Regulator
Rectifier
DCV
Battery
IG. switch
Pocket tester : 09900-25002
CAUTION
When making this test, be sure that the battery is
full-charged condition.
5-9 ELECTRICAL SYSTEM
67
99 V (at 5,000 rpm)
Standard NO-load perfor-
mance of magneto