FI SYSTEM DIAGNOSIS 4-26
“C22” OXYGEN SENSOR CIRCUIT MALFUNCTION
DETECTED CONDITION
Oxygen sensor signal is not input in ECU since then
more than 120 sec after the engine run.
●
Oxygen sensor, Oxygen sensor heater circuit open
or short.
●
Oxygen sensor, Oxygen sensor heater malfunction.
●
ECU malfunction.
POSSIBLE CAUSE
▣
▣
INSPECTION
1) Remove the right side front lower cover.
2) Turn the ignition switch “ ” (OFF) position.
3) Check the Oxygen sensor coupler for loose or
poor contacts.
Is OK?
NO
YES
●
BR or BW wire open or shorted
to ground, or poor
�
or
⑤
connection.
●
If wire and connection are OK,
intermittent trouble or faulty ECU.
●
Recheck each terminal and wire
harness for open circuit and poor
connection.
Replace the Oxygen sensor.
ECU Coupler
⑤
�
Summary of Contents for MS3 125
Page 6: ...NOTE Difference between photographs and actual motorcycles depends on the markets ...
Page 134: ...5 1 FUEL SYSTEM AND THROTTLE BODY FUEL SYSTEM ...
Page 139: ...FUEL SYSTEM AND THROTTLE BODY 5 6 THROTTLE BODY ...
Page 249: ...9 31 SERVICING INFORMATION WIRE AND CABLE ROUTING ...
Page 250: ...SERVICING INFORMATION 9 32 ...
Page 251: ...9 33 SERVICING INFORMATION ...
Page 252: ...SERVICING INFORMATION 9 34 ...
Page 253: ...9 35 SERVICING INFORMATION WIRING DIAGRAM ...
Page 254: ...SERVICING INFORMATION 9 36 ...