3-23 ENGINE
Cylinder distortion
Service limit
0.05 mm (0.002 in)
CYLINDER
▣
▣
CYLINDER DISTORTION
Check the gasketed surface of the cylinder for distor-
tion using a straightedge and thickness gauge, taking
a clearance reading at several places as indicated.
If the largest reading at any position of the straight-
edge exceeds the limit, replace the cylinder.
Thickness gauge : 09900-20806
Camshaft housing I.D
IN.
EX.
21.959 ~ 21.980 mm
(0.8645 ~ 0.8654 in)
21.959 ~ 21.980 mm
(0.8645 ~ 0.8654 in)
21.959 ~ 21.980 mm
(0.8645 ~ 0.8654 in)
Standard
Camshaft runout
(IN. & EX.)
Service limit
0.10 mm (0.004 in)
If the camshaft journal oil clearance exceeds the ser-
vice limit, measure the inside diameter of the
camshaft housing and outside diameter of the
camshaft journal. Replace the camshaft or the cylin-
der head and camshaft housing depending upon
which one exceeds the specification.
▣
▣
CAMSHAFT RUNOUT
Support the valve using a V-blocks and measure the
camshaft runout using the dial gauge. If the runout
exceeds the service limit, replace the camshaft with a
new one.
Small bore gauge : 09900-22401
Dial gauge : 09900-20606
Magnetic stand : 09900-20701
V-block : 09900-21304
IN.
EX.
Cam-
shaft
O.D
Standard
Summary of Contents for MS3 125
Page 6: ...NOTE Difference between photographs and actual motorcycles depends on the markets ...
Page 134: ...5 1 FUEL SYSTEM AND THROTTLE BODY FUEL SYSTEM ...
Page 139: ...FUEL SYSTEM AND THROTTLE BODY 5 6 THROTTLE BODY ...
Page 249: ...9 31 SERVICING INFORMATION WIRE AND CABLE ROUTING ...
Page 250: ...SERVICING INFORMATION 9 32 ...
Page 251: ...9 33 SERVICING INFORMATION ...
Page 252: ...SERVICING INFORMATION 9 34 ...
Page 253: ...9 35 SERVICING INFORMATION WIRING DIAGRAM ...
Page 254: ...SERVICING INFORMATION 9 36 ...
Page 257: ...Prepared by 1st Ed DEC 2007 Manual No 99000HP8810 Printed in Korea ...