NH 2100T 3. Hardware Specifications
3- 10
3.8 Operating Environment
Power Requirements
115 Vac ±10% 3.0A 60Hz , 350 Watt
230 Vac ±10% 1.5A 50Hz , 350 Watt
Power Connections
The NH 2100T ATM must be connected to a dedicated power circuit. This circuit must
consist of
LINE
,
NEUTRAL
and
GROUND
leads connected directly to the power circuit
breaker panel. This circuit cannot be shared with any other equipment.
Phone Line Requirements
The NH 2100T ATM must be connected to a dedicated phone line. This line must be a
direct dial “tone” or “pulse” line that is equipped with a standard telephone wall jack (RJ-
11). This line cannot be shared with any other equipment at the location.
Temperature
z
In storage
: 32°F - 123°F (0°C ~ 49°C)
z
While operating : 40°F - 95°F (5°C ~ 35°C)
Humidity
z
In storage
: 10% < RH < 90%, Non-Condensed
z
While operating : 25% < RH < 85%, Non-Condensed