2-5 PERIODIC MAINTENANCE
● Fill a washing pan of a proper size with non-
flammable cleaning solvent. Immerse the
elements in the cleaning solvent and wash
them clean.
● Squeeze the cleaning solvent out of the washed
element by pressing it under the palms of both
hands : do not twist or wring the element or it
will develop tears.
● Immerse the element in Hyosung genuine oil,
and squeeze the oil out of the element leaving it
slightly wet with oil.
● Fit the elements to the cleaner case properly.
Non-flammable
Cleaning solvent
Hyosung
genuine oil
Before and during the cleaning operation,
inspect the element for tears. A torn element
must be replaced.
Be sure to position the element snugly and
correctly, so that no incoming air will bypass it.
Remember, rapid wear of piston rings and
cylinder bore is often caused by a defective or
poorly fitted element.
CAUTION
③
②
①
Excessive valve clearance results in valve noise
and insufficient valve clearance results in valve
damage and reduced power. At the distances
indicated above, check and adjust the clearance to
the following specification.
The procedure for adjusting the valve clearance is
as follows :
● Remove the seat and fuel tank.
VALVE CLEARANCE
NOTE:
Inspect Initial 1,000 km and Every 4,000 km.
Summary of Contents for RX 125 -
Page 1: ...SERVICE MANUAL 99000 97100 SERVICE MANUAL HYOSUNG MOTORS MACHINERY INC RX125 RX 125 ...
Page 5: ......
Page 29: ...PERIODIC MAINTENANCE 2 16 ...
Page 94: ...FUEL SYSTEM 4 12 Start motor Piston Cylinder Oil cooler Cylinder head Crankcase Transmission ...
Page 118: ...CHASSIS 6 6 FRONT BRAKE yyy yyy yyy yyy yy yy y y ...
Page 126: ...CHASSIS 6 14 FRONT FORK ...
Page 132: ...CHASSIS 6 20 STEERING STEM ...
Page 143: ...6 31 CHASSIS SUSPENSION Service limit 10 20 mm Service limit 14 20 mm Service limit 10 20 mm ...
Page 150: ...CHASSIS 6 38 SPACER Apply grease to the spacer when installing Super grease A ...