2-3 PERIODIC MAINTENANCE
MAINTENANCE PROCEDURES
AIR CLEANER
NOTE :
Clean at least Every month.
If the air cleaner is clogged with dust, intake resis-
tance will increased with a resultant decrease in
output and an increase in fuel consumption.
Check and clean the element in the following man-
ner.
●
Stand the vehicle in the standing position
.
●
Remove the four bolts
①.
●
Remove the clamp screw
②
.
●
Remove the air cleaner case
⑤
.
●
Remove the element
④
from the cap
③
.
●
Fill a washing pan of a proper size with nonflammable
cleaning solvent. Immerse the element in the cleaning
solvent and wash it clean.
●
Squeeze the cleaning solvent out of the washed element
by pressing it between the palms of both hands : do not
twist or wring the element or it will develop tears.
●
Immerse the element in HYOSUNG genuine oil and
squeeze the oil out of the element leaving it slightly wet
with oil.
●
Fit the cleaner element to frame properly.
�
�
Before and during the cleaning operation,
inspect the element for tears. A torn element
must be replaced.
�
�
Be sure to position the element snugly and cor-
rectly, so that no incoming air will bypass it.
Remember, rapid wear of piston rings and
cylinder bore is often caused by a defective or
poorly fitted element.
CAUTION
�
Non-flammable cleaning solvent
�
2-stroke engine oil.
Summary of Contents for WOW 50
Page 1: ...SERVICE MANUAL 99000 93110 SERVICE MANUAL HYOSUNG MOTORS MACHINERY INC ...
Page 5: ......
Page 12: ...EXTERIOR ILLUSTRATION GENERAL INFORMATION 1 6 HEIGHT WIDTH WHEEL BASE LENGTH ...
Page 27: ......
Page 32: ...ENGINE 3 4 ...
Page 42: ...ENGINE 3 14 Front side Rear side Bushing Bushing Crankcase Crankcase ...
Page 71: ......
Page 73: ...4 1 FUEL SYSTEM REMOVAL Remove the front and rear fender CARBURETOR ...
Page 81: ......
Page 93: ...6 1 CHASSIS FRONT WHEEL AND BRAKE ...
Page 111: ......
Page 129: ...7 17 SERVICING INFORMATION B A EMERGENCY SWITCH CASE 09407 18401 ...