Freedom 38 PPA
Service Manual
809010
107
3 – System-Level Components
Replace the front panel
Remove the front panel
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the top cover and side panels from the system. See
4.
Release pressure from the air tank by turning the air condensate lever. See page 61. Release the pressure at the
separation tank by pulling the tab on the pressure relief valve.
5.
Remove the 4 screws and nuts to disconnect the CPC connector from the front panel.
6.
Remove the following components from the front panel.
Dynagen controller. See
Remove the Dynagen system controller
Air pressure gauge. See
Fuel shutoff relay. See
12 V circuit breaker. See
Remove the 12 V circuit breaker
Alternator lamp. See
ON/OFF power switch. See
Remove the ON/OFF power switch
120 V outlet. See
Remove the 120 V auxiliary outlet
120 V circuit breaker. See
Remove the 120 V auxiliary outlet circuit breaker
480 V outlet. See
Remove the 480 V auxiliary outlet
7.
Remove the emergency stop button by turning it counterclockwise. Remove the large nut that secures the
emergency stop assembly to the front panel.
Figure 38 – Emergency stop button exploded view
Kit number
Description
Kit: Front panel (hardware not included)
Kit: Labels for front panel controls
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...