Freedom 38 PPA
Service Manual
809010
185
6 – Air Compression Components
Replace the pressure relief valve on the separation tank
Remove the pressure relief valve on the separator tank
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Remove the plasma-side service panel.
3.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
4.
Drain the air tank to release pressure. See page 61.
5.
Release pressure from the separation tank by pulling the ring
on the pressure relief valve.
Figure 104
6.
Unscrew the pressure relief valve from the manifold.
Install the pressure relief valve on the separator tank
1.
Install the new pressure relief valve. Use part number 330116 thread sealant on the relief valve. Apply a thread seal
bead on 2–3 threads. Do not over-apply to avoid air line contamination.
2.
Reconnect the battery’s negative (-) ground cable.
3.
Replace the plasma-side service panel.
Kit number
Description
Kit: Manifold relief valve for the air compressor
1
1