Freedom 38 PPA
Service Manual
809010
3 – System-Level Components
Replace the 480 V auxiliary outlet
Remove the 480 V auxiliary outlet
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the 4 screws and washers
that secure the 480 V receptacle to the front panel.
Figure 34
4.
Pull the receptacle out from the front panel and loosen the box terminal screws
to disconnect the wires from the
receptacle. Mark the order of the wire colors and location to the receptacle. Check that the wires are stripped clean
and there are no stray wire strands
.
Kit number
Description
Kit: 480 V (60 A) auxiliary outlet replacement
Ground/neutral
White
WH
L1
Black
BK
L2
Red
RD
L3
Orange
OR
1
2
3
1
2
3