Replace the condensate release lever
The condensate release lever is a standard 1/4 inch brass 600 WOG (water, oil, gas) ball valve, Lance Supply
®
part
number 21-021. This is not available as a kit from Hypertherm and can be sourced locally if needed. This procedure
guides you through the replacement if necessary.
Remove the condensate release lever
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Drain the air tank to release pressure. See page 61.
4.
Remove the top cover and engine-side panel from the system. See
5.
Remove 7 screws from the front panel base plate. Unscrew 2 screws accessed from behind the front panel. These
are located near the 480 V auxiliary outlet electrical box. Set aside the front panel base plate and screws.