SPECIFICATIONS
HySpeed HT2000LHF
Instruction Manual
2-5
6
Digital Remote Voltage & Current
Control Console
Controls....................Voltage adjust potentiometer: Adjusts arc
cutting voltage and displays value on LEDs.
Current adjust potentiometer: Adjusts arc
current and displays value on LEDs.
Control range ...........Current: 40-200 amps/Voltage: 100-200 volts
Control resolution.....Current: 10 amps/ Voltage: 5 volts
Dimensions and Weight:
Width .......................................................11.4" (290 mm)
Height......................................................3" (76 mm)
Depth.......................................................13.4" (340 mm)
Weight .....................................................5.3 lbs (2.4 kg)
Programmable Remote Voltage & Current
Control Console
Controls....................None. Controlled through guidance CNC.
Control range ...........Current: 40-200 amps/Voltage: 100-200 volts
Control resolution.....Current: 10 amps/ Voltage: 5 volts
Dimensions and Weight:
Width .......................................................11.4" (290 mm)
Height......................................................3" (76 mm)
Depth.......................................................12.5" (318 mm)
Weight .....................................................5.3 lbs (2.4 kg)
Remote Current Control Console
Dimensions and Weight:
Width .......................................................6-1/2" (165 mm)
Height......................................................2-1/2" (64 mm)
Depth.......................................................8-5/8" (219 mm)
Weight .....................................................3 lbs (1 kg)
10.5" (267 mm)
11.4" (290 mm)
7/32"
(5.5 mm)
dia.
4 places
11.65" (296 mm)
5"
(127 mm)
0.5"
(13 mm)
Figure 2-4
Mounting Dimensions – Digital
Remote Voltage & Current Control Console
10.5" (267 mm)
11.4" (290 mm)
7/32" dia.
(5.5 mm)
4 places
11.65" (296 mm)
5"
(127 mm)
0.5"
(13 mm)
Figure 2-5
Mounting Dimensions – Programmable
Remote Voltage & Current Control Console
Figure 2-6
Mounting Dimensions –
Remote Current Control Console
5/32" ø (4 mm) – 4 places
3.38" (86 mm)
6.25" (159 mm)
8.5" (216 mm)
0.50" (13 mm)
1.17"
(30 mm)
6.50"
(165 mm)
Summary of Contents for HT2000LHF
Page 1: ...200 Volt Plasma Arc Cutting System Instruction Manual 803040 Revision 7 HySpeed HT2000LHF ...
Page 5: ......
Page 15: ...TABLE OF CONTENTS viii Hyspeed HT2000LHF Instruction Manual 6 ...
Page 109: ...MAINTENANCE 5 20 HySpeed HT2000LHF Instruction Manual 7 ...
Page 133: ......
Page 134: ...7 5 7 Figure 7 1 HT2000LHF Coolant Flow Diagram ...
Page 135: ......
Page 136: ...7 7 7 ...
Page 137: ......
Page 138: ...7 9 7 ...
Page 139: ......
Page 140: ...7 11 7 ...
Page 141: ......
Page 142: ...7 13 7 ...
Page 143: ......
Page 144: ...7 15 7 ...
Page 145: ......
Page 146: ...7 17 7 ...
Page 147: ......
Page 148: ...7 19 7 ...
Page 149: ......
Page 150: ...7 21 7 ...
Page 151: ......
Page 152: ...7 23 7 ...
Page 153: ......
Page 154: ...7 25 7 ...
Page 155: ......
Page 157: ......
Page 159: ......
Page 174: ...APPENDIX A ARGON HYDROGEN CUTTING AND GOUGING a 14 HySpeed HT2000LHF Instruction Manual 6 ...
Page 176: ...b 2 ...
Page 177: ...b 3 ...
Page 178: ...b 4 ...
Page 179: ...b 5 ...
Page 181: ...b 7 ...
Page 182: ...b 8 ...
Page 183: ...b 9 ...
Page 184: ...b 10 ...
Page 194: ...APPENDIX E AIR FILTERS e 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 196: ...APPENDIX F AERATION MANIFOLD FOR CUTTING ALUMINUM f 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 198: ...APPENDIX G IEC SYMBOLS g 2 Hyspeed HT2000LHF Instruction Manual 6 ...