Turn line disconnect
switch on
Push and hold
ON button (PB1)
Release ON button (PB1)
System initialization
is complete.
12VDC to the following interlocks:
1.
TSW1, TSW2
(Chopper temperature switches)
2.
TS1
(Power Supply transformer temperature switch)
3.
LS1
(Power Supply coolant level switch)
4.
PS3
(Power Supply shield pressure switches)
5.
PS1,
,
PS2
(Gas Console plasma pressure switches)
6.
TS2
(Power Supply coolant temperature switch)
7.
FS1
(Power Supply coolant flow switch – note this interlock
will not be satisfied until
M1
coolant pump is activated.)
CR1
(24V/120V relay) on Power Distribution
Board (PCB1) closes.
24VAC to
LT1
(Power Supply ON light)
PCB2
(Power Supply-
µ
P Control Board
24VAC interlock)
120VAC to
CH1
,
CH2
(Power Supply Choppers)
PCB3
(Power Supply Analog Board)
PCB4
(Power Supply Relay Board)
PCB9
(Power Supply THC Board)
CR2
(120V relay) on Power
Distribution Board (PCB1)
closes.
120VAC to
M2
,
M3
,
M4
(Power Supply
Fans)
M5-M8
(Power Supply Heat
Exchange Fans)
PCB2
(Power Supply-
µ
P
Control Board)
CR3
(240V relay) on Power
Distribution Board (PCB1)
closes.
240VAC to
M1
(Power Supply Coolant
Pump)
All STATUS LEDs on
PCB5
(Interlock Display
Board) are extinguished.
Correct
Interlock
Problem
Correct
Interlock
Problem
First 5 interlocks
listed above
satisfied
?
All interlocks
listed above
satisfied
?
No
No
Yes
Yes
MAINTENANCE
HySpeed HT2000LHF
Instruction Manual
5-3
6
Gas Console
Inspection
Inspect the gas console on a routine basis.
• Check the exterior for any damage. Look for damaged glass tubes in the flowmeters and check the
pressure gauges for damage.
• Inspect all interconnecting cables, hoses and leads for wear and damage. Ensure that all connections are
tight and that there are no leaks. Do not overtighten fittings.
Cleaning
Keep the flowmeters and pressure gauges free of dirt, dust and foreign matter.
Start Sequence
Shaded boxes represent
action taken by the operator.
Summary of Contents for HT2000LHF
Page 1: ...200 Volt Plasma Arc Cutting System Instruction Manual 803040 Revision 7 HySpeed HT2000LHF ...
Page 5: ......
Page 15: ...TABLE OF CONTENTS viii Hyspeed HT2000LHF Instruction Manual 6 ...
Page 109: ...MAINTENANCE 5 20 HySpeed HT2000LHF Instruction Manual 7 ...
Page 133: ......
Page 134: ...7 5 7 Figure 7 1 HT2000LHF Coolant Flow Diagram ...
Page 135: ......
Page 136: ...7 7 7 ...
Page 137: ......
Page 138: ...7 9 7 ...
Page 139: ......
Page 140: ...7 11 7 ...
Page 141: ......
Page 142: ...7 13 7 ...
Page 143: ......
Page 144: ...7 15 7 ...
Page 145: ......
Page 146: ...7 17 7 ...
Page 147: ......
Page 148: ...7 19 7 ...
Page 149: ......
Page 150: ...7 21 7 ...
Page 151: ......
Page 152: ...7 23 7 ...
Page 153: ......
Page 154: ...7 25 7 ...
Page 155: ......
Page 157: ......
Page 159: ......
Page 174: ...APPENDIX A ARGON HYDROGEN CUTTING AND GOUGING a 14 HySpeed HT2000LHF Instruction Manual 6 ...
Page 176: ...b 2 ...
Page 177: ...b 3 ...
Page 178: ...b 4 ...
Page 179: ...b 5 ...
Page 181: ...b 7 ...
Page 182: ...b 8 ...
Page 183: ...b 9 ...
Page 184: ...b 10 ...
Page 194: ...APPENDIX E AIR FILTERS e 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 196: ...APPENDIX F AERATION MANIFOLD FOR CUTTING ALUMINUM f 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 198: ...APPENDIX G IEC SYMBOLS g 2 Hyspeed HT2000LHF Instruction Manual 6 ...