MAINTENANCE
5-6
HySpeed HT2000LHF
Instruction Manual
6
Troubleshooting
The troubleshooting section is presented by following normal operational sequence.
Before troubleshooting for specific problems, be sure that the unit passes
Initial Checks
as outlined earlier in this
section.
WARNING
SHOCK HAZARD: Always use caution when servicing a power supply when the covers are
removed. Dangerous voltages exist within the power supply which could cause injury or death.
If questions or problems arise during servicing, call the Hypertherm Technical Services Department
listed at the front of this manual.
1. The green POWER ON pushbutton
switch PB1 is pressed, but the fans
are not operating and the green
POWER ON indicator does not
illuminate.
1.1. The POWER ON (I) PB1 pushbutton is defective.
Check that the switch is operating correctly. The POWER
ON switch is normally open.
1.2. The POWER OFF (0) PB2 pushbutton is defective.
Check that the switch is operating correctly. The POWER
OFF switch is normally closed.
1.3. No jumper for PB2A and PB2B at TB5.
TB5 terminals 1&2 and 4&5 need a jumper if there is no
optional remote I/O cable for switching the power supply on
and off.
1.4. Associated wiring not making good contact.
Check wiring and repair or replace, if necessary.
2. The green POWER ON pushbutton
switch PB1 is pressed, the POWER
ON indicator illuminates, but the
fans are not running.
2.1. CR2 on the power distribution board PCB1 is defective.
Check that CR2 switches when the POWER ON pushbutton
is pressed. See Figure 5-3 for location of CR2. If CR2 is
defective, replace PCB1.
2.2. Connector from the power distribution board is not seated
securely.
Check pins, connectors and associated wiring for continuity.
Repair or replace, if necessary.
3. The green POWER ON pushbutton
switch PB1 is pressed, the fans are
operating, but the green POWER
ON indicator does not illuminate.
3.1. Pushbutton PB1 was not held down for a long enough
period of time.
Press and hold PB1 for a minimum of 5 seconds.
3.2. Relay CR1 on the power distribution board is defective.
Check that CR1 switches when the POWER ON pushbutton
is pressed. See Figure 5-3 for location of CR1. If CR1 is
defective, replace PCB1.
Problem
Possible Causes
/ Solutions
Summary of Contents for HT2000LHF
Page 1: ...200 Volt Plasma Arc Cutting System Instruction Manual 803040 Revision 7 HySpeed HT2000LHF ...
Page 5: ......
Page 15: ...TABLE OF CONTENTS viii Hyspeed HT2000LHF Instruction Manual 6 ...
Page 109: ...MAINTENANCE 5 20 HySpeed HT2000LHF Instruction Manual 7 ...
Page 133: ......
Page 134: ...7 5 7 Figure 7 1 HT2000LHF Coolant Flow Diagram ...
Page 135: ......
Page 136: ...7 7 7 ...
Page 137: ......
Page 138: ...7 9 7 ...
Page 139: ......
Page 140: ...7 11 7 ...
Page 141: ......
Page 142: ...7 13 7 ...
Page 143: ......
Page 144: ...7 15 7 ...
Page 145: ......
Page 146: ...7 17 7 ...
Page 147: ......
Page 148: ...7 19 7 ...
Page 149: ......
Page 150: ...7 21 7 ...
Page 151: ......
Page 152: ...7 23 7 ...
Page 153: ......
Page 154: ...7 25 7 ...
Page 155: ......
Page 157: ......
Page 159: ......
Page 174: ...APPENDIX A ARGON HYDROGEN CUTTING AND GOUGING a 14 HySpeed HT2000LHF Instruction Manual 6 ...
Page 176: ...b 2 ...
Page 177: ...b 3 ...
Page 178: ...b 4 ...
Page 179: ...b 5 ...
Page 181: ...b 7 ...
Page 182: ...b 8 ...
Page 183: ...b 9 ...
Page 184: ...b 10 ...
Page 194: ...APPENDIX E AIR FILTERS e 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 196: ...APPENDIX F AERATION MANIFOLD FOR CUTTING ALUMINUM f 2 Hyspeed HT2000LHF Instruction Manual 6 ...
Page 198: ...APPENDIX G IEC SYMBOLS g 2 Hyspeed HT2000LHF Instruction Manual 6 ...