APPENDIX F SYSTEM GROUNDING
HT4001 Instruction Manual
f-3
The preferred cable routing for this configuration is as shown, but it is acceptable to “daisy-
chain” the grounds for the gas console and other equipment to the RHF console. The RHF
console should NOT be daisy-chained through the other components to the work table.
Plasma Power Supply
Power Cord
Ground
(PE)
Ferrite Choke
Other Equipment
receiving power from the
plasma power supply
(PE)
(PE)
(PE)
RHF Console
Gas Console
Work Table
Supplementary
Grounding Rod
Figure f-2 Alternate Ground Connection Configuration