Maintenance
5-14
HPR130XD Auto Gas –
806330
Error code troubleshooting – error codes 044 to 046
Error code
number
Name
Description
corrective action
044
Low plasma
gas pressure
Plasma gas pressure under
lower limit of
0.34 bar (5 psi) – preflow
3.45 bar (50 psi) – cutflow
(cutting)
0.34 bar (5 psi) – cutflow
(marking)
1. Inspect gas supply pressure and volume of gas
remaining in supply tanks.
2. Verify the gas regulator settings on gas console with the
parameters in the cut charts.
3. See
Setting the supply regulators
(
Installation
section).
4. Perform gas leak tests (
Maintenance
section).
045
High plasma
gas pressure
Plasma gas pressure over
upper limit of:
7.58 bar (110 psi) – manual
9.65 bar (140 psi) – auto
1. Verify gas supply pressure settings.
2. Verify gas regulator settings on gas console with cut
chart.
3. See
Setting the supply regulators
(
Installation
section).
4. Solenoid at off-valve is not opening. Verify power to
valves, disconnect plasma and shield hoses exiting off-
valve. If pressures decrease a valve is not functioning or
no power to the valve.
046
Low line
voltage
Line voltage is close to or
less than the lower limit of
102 VAC (120 VAC -15%).
The normal lower limit for
operation is
108 VAC (120 VAC -10%).
1. Verify input-line voltage at PCB2 in the power supply
(also PCB1 in the cooler for HPR400XD systems).
Voltage needs to be within 10% of nominal (120 VAC).
2. Verify fuses on PCB2 in the power supply.
3. Verify 120 VAC voltage on plug J2.4, pins 3 and 4 on
PCB2 in the power supply.
4. For HPR400XD systems, verify the voltage on PCB1 in
the cooler with a DC volt meter. It should be about 0.415
VDC between TP23 and TP2 on PCB1.
5. If AC voltage on PCB2, J2.4, pins 3 and 4, is greater
than 108 VAC and DC voltage between TP23 and TP2
on PCB1 is less than 0.38 VDC, verify minimum 108
VAC voltage on plug J4, pins 1 and 2 on PCB1. Verify
the wiring between PCB2 in the power supply and J4 on
PCB1. If the voltage on plug J4 is greater than 108 VAC,
but the DC voltage on TP23 and TP2 is less than 0.38,
replace PCB1.
6. If the AC voltage on PCB2 in the power supply at J2.4,
pins 3 and 4, is greater than 108 VAC and the DC
voltage between TP23 and TP2 on PCB1 in the cooler
(HPR400XD only) is also greater than 0.38 VDC, verify
the CAN link between PCB3 in the power supply and
PCB1 in the cooler.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...