Maintenance
5-18
HPR130XD Auto Gas –
806330
Error code troubleshooting – error codes 071 to 075, 273 to 275
Error code
number
Name
Description
corrective action
071
Coolant
overtemp
Torch coolant has
overheated.
1. Verify that the large fan in the cooler (HPR400XD only) is
running.
2. Blow dust out of the coolerr (HPR400XD only), especially
from the heat exchanger.
3. Verify that the voltage on the rear side of J1.5
pins 6 and 8, is equal to or lower than 2.8 VDC.
4. If voltage is low, inspect wiring between coolant
temperature sensor and J1.5, pins 5 and 6, for shorts to
wires or ground.
5. If wiring is good, the coolant has overheated; let system
idle with the fans running for 30 minutes to cool.
6. Replace the coolant temperature sensor if it is open or
shorted. Sensor part number is 229224.
072
Auto gas,
control board
overtemp
Auto gas
only
Control board has
exceeded 90°C (194°F).
Verify that the airflow to the gas console is not restricted.
073
Primary
273
Secondary
Chopper 3
overtemp
HPR400XD
only
Chopper 3 has
overheated.
1. Verify that all chopper fans are operating properly.
Spinning fan blades should be difficult to see.
2. Blow dust out of system, especially from fans and heat sink
of chopper.
3. Verify that the voltage on rear side of J3.202, pins 8 and 9
on PCB3, is less than or equal to 2.9 VDC.
4. If the voltage is low, verify correct wiring between chopper
temperature sensor and J3.202 pins 7 and 8.
5. If wiring is good and overtemp error does not clear after
30 minutes of the power supply idling with the fans
running, replace the chopper.
074
Primary
274
Secondaryy
Chopper 4
overtemp
HPR400XD
only
Chopper 4 has
overheated.
1. Verify that all chopper fans are operating properly.
Spinning fan blades should be difficult to see.
2. Blow dust out of system, especially from fans and heat sink
of chopper.
3. Verify that the voltage on rear side of J3.202, pins 11 and
12 on PCB3, is less than or equal to 2.9 VDC.
4. If the voltage is low, verify correct wiring between chopper
temperature sensor and J3.202 pins 10 and 11.
5. If wiring is good and overtemp error does not clear after
30 minutes of the power supply idling with the fans
running, replace the chopper.
075
Primary
275
Secondary
Low current
on CS3
HPR400XD
only
A current less than
10 amperes has
been detected by
current sensor 3.
See the chopper test later in this section.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...