Maintenance
5-22
HPR130XD Auto Gas –
806330
Error code troubleshooting – error codes 134 to 140, 334 and 338
Error code
number
Name
Description
corrective action
134
Primary
334
Secondary
Chopper 1
overcurrent
Chopper 1 current
feedback has exceeded
160 amperes.
1. Verify that the wiring between CS1 and PCB3 is correct
and not damaged.
2. Measure voltage across current sensor.
a) Red to black = +15 VDC, Green to black = -15 VDC,
white to black = 0 VDC at idle and varies with current
output (4 VDC = 100 A).
b) If possible, take a voltage reading on current sensor
while trying to cut. Ratio is 4 VDC = 100 A.
c) If the current sensor voltage is approximately 6.4 VDC or
greater at idle, replace the current sensor.
3. Remove connector JA.1 from the chopper and verify that
LED1 is extinguished.
a) If LED1 is extinguished with the connector removed, then
reconnect JA.1 and try to fire the torch. If the chopper
still goes into overcurrent, replace the chopper.
b) If the chopper does not go into overcurrent, replace
PCB3.
138
Primary
338
Secondary
Chopper 2
overcurrent
HPR260XD
HPR400XD
only
Chopper 2 current
feedback has exceeded
160 amperes.
1. Verify that the wiring between CS2 and PCB3 is correct
and not damaged.
2. Measure voltage across current sensor.
a) Red to black = +15 VDC, Green to black = -15 VDC,
white to black = 0 VDC at idle and varies with current
output (4 VDC = 100 A).
b) If possible, take a voltage reading on current sensor
while trying to cut. Ratio is 4 VDC = 100 A.
c) If the current sensor voltage is approximately 6.4 VDC or
greater at idle, replace the current sensor.
3. Remove connector JB.1 from the chopper and verify that
LED1 is extinguished.
a) If LED1 is extinguished with the connector removed, then
reconnect JB.1 and try to fire the torch. If the chopper
still goes into overcurrent, replace the chopper.
b) If the chopper does not go into overcurrent, replace
PCB3.
139
Purge
time-out error
The purge cycle did
not complete within
3 minutes.
This is a warning for a possible gas restriction in the leads.
1. Verify that there are no restrictions in the plasma and shield
hoses.
2. Verify that the inlet gas pressures are set to the proper
levels.
140
Pressure
transducer
1or 8 error
Auto gas
only
Faulty transducer or
control board in the
metering console or the
selection console.
1. Verify that transducer P1 in the selection console is working
properly. Replace if necessary.
2. Verify that transducer P8 in the metering console is working
properly. Replace if necessary.
3. Verify that the control boards in the metering and selection
consoles are working properly. Replace if necessary.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...