Maintenance
HPR130XD Auto Gas –
806330
5-29
Plasma system operation with pump time-out
No
HPR
power supply
power-up
Error output
on
If 30 minutes has
passed since the
last start, turn OFF
the pump
Fire the torch
and begin
cutting
If the pump has timed out,
turn on the NOT READY
FOR START signal and
turn on the pump
Purge cycle begins, NOT
READY FOR START
signal is active
System is in IDLE state
waiting for a START signal,
NOT READY FOR START
signal is inactive
PLASMA START
signal active
STAR signal
Is the flow
sensor satisfied?
Purge timer done
Yes
Yes
Yes
START signal
removed
No
No
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...