Maintenance
5-42
HPR130XD Auto Gas –
806330
5. Turn ON the power supply, and note the coolant flow rate shown on the CNC display.
If the flow shown on the CNC screen is more than 0.8 gpm, replace the check valve. Coolant will drain out of the torch
during every consumable change if the check valve is bypassed.
If the flow shown on the CNC screen is less than 0.8 gpm, replace the flow switch.
Note: The check valve must be oriented correctly. The arrow points up, as shown.
Check valve orientation
Pump and motor troubleshooting
Is the motor LED illuminated on the control board?
Is the motor on?
If the LED is illuminated, but the pump is not running, turn the pump on manually.
If the motor will not turn on, verify that the fuse is OK, and make sure there is power to the motor.
If you are still not getting flow from the pump, verify that the solenoid valve and check valve are working correctly.
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...