7-23
Unit 1
Interface
CNC
(Customer Supplied)
041993
CONTROL BOARD
1 2 3 4
S100
4
3
J303
2
1
2 3 4
1
J300A
J300B
CNC Interface Cable
J300A
S100
J300B
J303
CONTROL BOARD
Unit 2
J300A
S100
J300B
J303
CONTROL BOARD
Unit 3
J300A
J300B
S100
J303
CONTROL BOARD
Unit 4
CNC Interface Cable
CNC Interface Cable
CNC Interface Cable
Serial ID
Dipswitch
Machine Motion
Jumper Block
Jumper Block
Machine Motion
Dipswitch
Serial ID
Jumper Block
Machine Motion
Dipswitch
Serial ID
Jumper Block
Machine Motion
Dipswitch
Serial ID
J106
2
1
J107
1 2
J106
1 2
1 2
J107
J106
1 2
1 2
J107
J106
1 2
1 2
J107
Optional Multi-System Interface
5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4
S101
ON
041993
1 2 3 4
S101
ON
041993
1 2 3 4
S101
ON
041993
1 2 3 4
S101
ON
4
3
2
1
2 3 4
1
4
3
2
1
2 3 4
1
4
3
2
1
2 3 4
1
HPR PAC
Dry Cutting System
HPR PAC
Dry Cutting System
HPR PAC
Dry Cutting System
HPR PAC
Dry Cutting System
4
3
2
1
1
A
4
3
2
A
B
C
D
B
C
D
120
RX
Termination
Termination
120
TX
ELEC SCH:HPR130XD POWER SUPPLY W/AUTO
D
013376
SHEET 19 OF 22
Notes:
1) For single system installations set Serial ID (S100), and Machine Motion (J303) as shown in Unit 1,
jumpers J106 and J107 must be closed.
2) On multi-system installations refer to the illustration.
Jumpers J106 and J107 are left open on all systems except for the very last system where they are in the closed position.
Termination resistors (120-ohm) or termination jumpers must be installed/set at the CNC for
each of the RS-422 RX and TX signal pairs.
3) If a Hypertherm Automation Controller is being used, and there are intermittent communication failures (PS Link Failure),
try removing the jumpers on J106 and J107 on the control board, and the termination jumper (J6 or J8) on the
serial isolation board in the controler. Only remove the termination jumper on the serial isolation board that is
connected to the HPR power supply. See sheet 17 for more details.
Switch 1 is in the On position
Switches 2-8 are in the Off position
S301
1 2
3 4 5 6 7 8
Dipswitch setting example:
2
1
3
4
5
6
7
8
ON
ON
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...