Appendix B – CnC interfACe protoCol
b-16
HPR130XD Auto Gas –
806330 Revision 1
ID
command
System
Description
121 LEAK_CHECK_MODE
Manual gas system
Auto gas system
This command will put the system into leak mode. There are
3 modes, mode #1 is the inlet leak check mode. This is used to
see if the inlet solenoids are allowing gas to pass through the valve
even when they are closed.
Mode #2 is the system leak check mode which will test for leaks
to atmosphere within the system. Mode #3 is the Burkert valve
flow test. For automatic gas consoles only.
For the inlet leak test, the system should have 0 psi on all gas
channels, and hold at this pressure.
For the system leak test, the system should charge all gas lines,
then hold the pressure.
The Burkert flow test checks for an expected PWM value for a set
pressure and does a gas ramp-down test.
NotE: this test is preformed using 130 A o
2
/ Air
consumables and setting the 30 A o
2
/ o
2
process
Each test takes about 40 seconds to complete.
This command will only be accepted when the power supply is in
the state IDLE2 (03).
After leak checking is complete the system must be set to mode 0.
An error code will reflect the state of the test. Using the GET_
LAST_ERROR command, you can get the result of the test.
12 = Test in progress
13 = Test passed
14 = Cut gas channel #1 failed
15 = Cut gas channel #2 failed
16 = Plasma ramp-down test failed (Burkert test only)
17 = Shield ramp-down test failed (Burkert test only)
Data:
Mode 0 = run
1 = Inlet leak check
2 = System leak check
3 = Burkert flow check
Return value:
Time for the test to run in seconds, 0 = not accepted
Sample:
>1211C5<
>12140F8< “40 second test”
command table (11 of 14)
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...