Appendix B – CnC interfACe protoCol
HPR130XD Auto Gas –
806330 Revision 1
b-21
Error codes
ID
Name
Description
000
NO ERROR
System is ready to run.
009
FLOW SWITCH TEST
When the pump is restarted after a pump timeout (30 minutes
without a start signal) the system will test the flow switch to make
sure there is sufficient flow before firing the torch.
011
NO_ACTIVE_PROCESS
The power supply receives an invalid current setting from a CNC.
012
TEST IN PROGRESS
One of the gas test modes is running.
013
TEST PASSED
The test completed successfully.
014
CUT GAS CHANNEL #1 FAIL
The gas pressure is dropping on channel #1, indicating a leak.
015
CUT GAS CHANNEL #2 FAIL
The gas pressure is dropping on channel #2, indicating a leak.
016
PLASMA RAMP-DOWN FAIL
Pump output has exceeded 200 psi.
017
SHIELD RAMP-DOWN FAIL
Shield pressure did not decrease in the allotted time.
018
PUMP OVER PRESSURE
Pump output has exceeded 13.79 bar (200 psi.)
020
NO PILOT ARC
No current detected from chopper at ignition and before
1-second timeout.
021
NO ARC TRANSFER
No transfer signal detected before 500-msec timeout.
024 Primary
224 Secondary LOST CURRENT CH1
After transfer, lost the chopper current signal.
025 Primary
225 Secondary LOST CURRENT CH2
After transfer, lost the chopper current signal.
026 Primary
226 Secondary LOST TRANSFER
After transfer, lost the transfer signal.
027 Primary
227 Secondary LOST PHASE
When main contactor is engaged, no “phase OK” input.
028 Primary
228 Secondary LOST CURRENT CH3
After transfer, lost the chopper current signal.
030
GAS SYSTEM ERROR
A failure has occurred in the gas system.
031 Primary
231 Secondary START LOST
Start signal was removed before steady-state operation.
032
HOLD TIMEOUT
Hold signal was applied for longer than 60 seconds.
033
PRE CHARGE TIMEOUT
Gas console was not able to charge the gas lines to the correct
pressure.
034 Primary
234 Secondary PRE CHARGE TIMEOUT
Gas console was not able to charge the gas lines to the correct
pressure.
042
LOW NITROGEN PRESSURE
Nitrogen gas pressure under lower limit of 2.07 bar (30 psi) –
cutting, 0.34 bar (5 psi) – marking
044
LOW PLASMA GAS PRESSURE
Gas pressure under lower limit of 0.34 bar (5 psi) – pre-flow
3.45 bar (50 psi) – cutflow (cutting) 0.34 bar (5 psi) – cutflow
(marking).
045
HIGH PLASMA GAS PRESSURE Gas pressure over upper limit of 7.58 bar (110 psi).
046
LOW LINE VOLTAGE
Line voltage is under lower limit of 102 VAC (120 VAC -15%).
047
HIGH LINE VOLTAGE
Line voltage is over upper limit of 138 VAC (120 VAC +15%).
048 Primary
248 Secondary CAN ERROR
An error occurred with the CAN communication system.
050 Primary
250 Secondary START ON AT INIT
Start signal input is active during power-up.
053
LOW SHIELD GAS PRESSURE Gas pressure is under lower limit of 0.14 bar (2 psi).
Summary of Contents for HyPerformance HPR130XD
Page 1: ...HyPerformance Plasma HPR130XD Auto gas Instruction manual 806330 Revision 3 ...
Page 16: ...Table of Contents viii HPR130XD Auto Gas 806330 ...
Page 26: ...Specifications 2 2 HPR130XD Auto Gas 806330 ...
Page 38: ...Specifications 2 14 HPR130XD Auto Gas 806330 ...
Page 48: ...Installation 3 10 HPR130XD Auto Gas 806330 ...
Page 59: ...Installation HPR130XD Auto Gas 806330 3 21 1X1 J103 J300 Female Male 5 6 5 6 3X1 3X2 3X3 3X4 ...
Page 94: ...Installation 3 56 HPR130XD Auto Gas 806330 ...
Page 101: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 7 Diagnostics screen ...
Page 102: ...Operation 4 8 HPR130XD Auto Gas 806330 Revision 2 Test screen ...
Page 103: ...Operation HPR130XD Auto Gas 806330 Revision 2 4 9 Cut chart screen ...
Page 152: ...Operation 4 58 HPR130XD Auto Gas 806330 Revision 2 ...
Page 236: ...7 4 HPR130XD Auto Gas 806330 Discrete output functionality ...
Page 294: ...Appendix B CNC Interface Protocol b 28 HPR130XD Auto Gas 806330 Revision 1 ...
Page 302: ...4 HPR130XD Auto Gas 806330 ...