3-4
S
ETUP
Operator Manual
400V or 480V
200V or 208V
230V or 240V
VOLTAGE CONFIGURATIONS
The 208/240/480V Powermax1100 power supplies are shipped to operate at 480 volts. The
200/230/400V and 230/400V CE Powermax1100 power supplies are shipped to operate at 400 volts.
To operate at an alternate voltage, remove the rear panel, and configure the wires and jumpers on TB2
and TB3 as shown below.
Notes: •
When switching from the 480V or 400V configuration, use the spare jumper in the clip located
on the floor of the power supply.
•
If using the 600V transformer option kit, configure the Powermax1100 for 480V.
WARNING
SHOCK HAZARD: Always turn off the power, unplug the cord and wait 5 minutes before
removing any power supply cover. If the power supply is directly connected to a line
disconnect switch, place switch in the OFF position. In the U.S., use a "lock-out / tag-out"
procedure until the service or maintenance work is complete. In other countries, follow
appropriate local or national safety procedures.
Figure 3-3 200V or 208V
Configuration
Figure 3-4 230V or 240V
Configuration
Figure 3-5 400V or 480V
Configuration
Figure 3-2 Rear Panel
Remove 8 screws to
remove panel
Black
White
Black
White
TB2
TB3
Black
White
Approximate location
of TB2 and TB3
TB2
TB3
TB2
TB3
Jumper