Powermax125
Service Manual 808070
223
9 – Power Supply Component Replacement
Replacing the gas filter assembly
Remove the gas filter assembly
1.
Complete the following procedures:
a.
Disconnect the power and gas supply
b.
c.
d.
2.
Disconnect the 2 wire terminals from the top of the pressure switch.
3.
Remove the screw securing the 2 ground wires to the gas filter housing.
4.
Push in the plastic ring on the push-to-connect fitting. Gently pull the top of the rear panel away from the power
supply until the gas tube pulls out of the push-to-connect fitting.
Figure 82
Kit number
Description
Kit: Powermax65/85/105/125 gas filter assembly
1
2
3
4
5
6
7
8
1
Rear panel
2
Pressure switch
3
Gas fitting
4
Gas filter housing
5
Ground wire screw
6
Gas tube
7
Push-to-connect fitting
8
Wire terminals