Powermax125
Service Manual 808070
225
9 – Power Supply Component Replacement
7.
Connect the wire terminals to the top of the pressure switch (blue wire closest to the center panel).
8.
Install the filter element, retaining nut, and filter bowl. See
Install the gas filter element
9.
Complete the following procedures:
a.
b.
Install the power supply cover
c.
Reconnect the power and gas supply.
Replacing the solenoid valve
Remove the solenoid valve
1.
Complete the following procedures:
a.
Disconnect the power and gas supply
b.
c.
d.
2.
Unplug the J6 connector from the back side of the power board.
Figure 84
3.
Pull the solenoid valve power wires and connector through the left grommet from the fan side of the power supply.
See
4.
Push in the plastic ring on the pressure transducer fitting while pulling the pressure transducer out of the solenoid
valve.
Kit number
Description
Kit: Powermax105/125 regulator/solenoid valve
J1
J2
J3
J5
J6
J1
J2
J3
J5
J6