236
Powermax125
Service Manual 808070
9 – Power Supply Component Replacement
Replacing the work lead receptacle
1.
Complete the following procedures:
a.
Disconnect the power and gas supply
b.
c.
2.
Remove the bolt securing the work cable to the work lead receptacle.
3.
Remove the nut and lock washer securing the work lead receptacle to the front panel.
4.
Push the work lead receptacle out through the front panel.
Figure 93
Kit number
Description
Kit: Powermax105/125 work lead receptacle (power supply side)
1
2
3
4
5
1
Work lead receptacle
2
Bolt
3
Work cable
4
Nut
5
Lock washer