9 – Power Supply Component Replacement
8.
Lift up the end of the power supply base, and carefully
slide the front panel against the base.
9.
Tighten the 3 mounting screws in the bottom of the front
panel to 23 kg-cm (20 inch-pounds).
10.
Secure the electrode wire to the power board at J28 by
tightening the screw to 23 kg-cm (20 inch-pounds).
11.
Secure the output inductor wires to the power board by
tightening the screw to 40.3 kg-cm (35 inch-pounds).
12.
Complete the following procedures:
a.
b.
c.
d.
Install the power supply cover
e.
Reconnect the power and gas supply.
Figure 98
Front panel mounting screws
J22
J21
J20
J19
J27
WORK
LEAD
J26
J25
+
_
+
_
RED
J18
ORG
J17
RED
J32
J11
B
R
J28
C152
C151
TP7
TP9
TP8
W
R
B
Output inductor wires mounting
screw
Electrode wire mounting screw (J28)
Power board