Powermax125
Service Manual 808070
277
10 – Torch Component Replacement
4.
Apply threadlocker (330103) to the threads of the gas tube fitting on the torch body. Be careful not to get any
threadlocker on the conical surface of the gas tube fitting to avoid damage to the torch.
Figure 133
5.
Thread the torch body into the torch lead until snug.
The white wires of the lead should be facing up.
6.
Use a 3/8-inch and 1/2-inch wrench together (or 2 adjustable wrenches) to tighten the gas fitting that secures the
torch body to the torch lead to 69.1 kg-cm (60 inch-pounds).
7.
Tighten the pilot terminal screw to 17.3 kg-cm (15 inch-pounds).
The wire should go down into the left handle. Bend the terminal slightly if necessary.
8.
Complete the following procedures:
a.
Install all of the torch components that you removed. See
b.
Reconnect the torch and gas supply, and turn ON (
I
) the power.
CAUTION!
Do not get any threadlocker on the conical surface of the gas tube fitting to avoid causing damage
to the torch. If any threadlocker does get on this surface, clean it off immediately.
Conical surface of the gas tube
fitting