SPECIFICATIONS
powermax1650
Service Manual
2-3
0
Standard Model
Input Voltage
200-208
230-240
400
480
600
Input Current at 16kw Output
53
46
27
22
21
Input Current during Arc
Stretch
75
72
42
34
33
Recommended Fuse
80
80
50
40
40
CE Model
Input Voltage
230
400
Input Current at 16kw Output
46
27
Input Current during Arc
Stretch
72
42
Recommended Fuse
80
50
Three Phase
Three Phase
Power Connection
The Powermax1650 is a universal power supply that configures itself to operate with AC voltages from 200 to 600
3PH (230-400 3PH for CE model). Use a line disconnect switch for each power supply so that the operator can turn
off the power supply quickly in an emergency. Locate the switch so it is easily accessible to the operator. The
interrupt level of the switch must be equal to or exceed the continuous rating of the fuses. Use slow-blow fuses
rated per local and national electrical codes.
Engine Drives
When using an engine drive to power the Powermax1650:
• The engine drive must be dedicated to powering the plasma cutting system.
• Engine drive operation:
1. Set the engine drive output to 3 phase AC.
2. Plug the Powermax1650 power cord into the power outlet.
3. Set the engine drive to the maximum output (see table below).
• Use unshielded consumables if you experience difficulty cutting thicker material (non-CE systems only).
Standard Unit
3 Phase, 50/60 hz, 200 – 600 VAC (480 VAC recommended for best performance)
CE Unit
3 Phase, 50/60 hz, 230 – 400 VAC (400 VAC recommended for best performance)
Engine Drive Rating
PMX1650 Output Current
Performance
30 kw
100 A
Full Arc Stretch
22.5 kw
100 A
Limited Arc Stretch
75 A
Full Arc Stretch
15 kw
75 A
Limited Arc Stretch
50 A
Full Arc Stretch