Maintenance and RepaiR
5-2
powermax
45
Operator Manual
Perform routine maintenance
dANgeR
ELECTRIC SHOCK CAN KILL
disconnect electrical power before performing any maintenance. All work requiring
removal of the power supply cover must be performed by a qualified technician.
every use:
Check the indicator lights and correct any fault
conditions.
Inspect the consumables for proper installation and wear.
every 3 months:
Replace any damaged labels.
Inspect the trigger for damage. Inspect the torch body for cracks
and exposed wires. Replace any damaged parts.
Inspect the power cord and plug. Replace if
damaged.
Inspect the torch lead. Replace if damaged.
every 6 months:
or
Clean the inside of the power supply with compressed air or a
vacuum.