TroubleshooTing and sysTem TesTs
5-16
powermax
65/85
Service Manual
IGBT device test using a non-Hypertherm tester
The device tester shown on page 5-15
Schematic for building an IGBT tester
has one LED and one pushbutton switch that
are used in combination to perform two tests.
Note: Before an IGBT can be tested, it must be electrically isolated from all circuits. If the IGBT is installed in a power
supply, remove the power board and any lead connections before testing.
1. Inspect the IGBT for cracks or black marks. If damaged, replace the IGBT.
2. Verify that the 9 V battery reads greater than (>) 8.0 V.
3. Connect the test leads as shown below.
4. With the test leads connected and without pressing the pushbutton switch, the LED should not illuminate. If the
LED is illuminated, then the IGBT is shorted. Replace the IGBT.
5. With the test leads connected, press the pushbutton switch. This time, the LED should illuminate. If the LED does
not illuminate, then the IGBT is open. Replace the IGBT.
Yellow lead
Gate 1 (G1)
Black lead
Emitter 1 (E1)
Red lead
Collector 1 (C1)
IGBT, Inverter
test 1
IGBT, PFC
Yellow lead
Gate (G)
Red lead
Collector (C)
Black lead
Emitter (E)
IGBT, Pilot arc
IGBT, Inverter
test 2
Yellow lead
Gate 2 (G2)
Black lead
Emitter 2 (E2)
Red lead
Collector 2 (C2)
Yellow lead
Gate (G)
Red lead
Collector (C)
Black lead
Emitter (E)
Summary of Contents for Powermax 65
Page 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Page 10: ...vi powermax65 85 Service Manual ...
Page 16: ...Table of Contents xii powermax65 85 Service Manual ...
Page 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Page 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Page 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Page 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...