230V CE INSTALLATION
230V CE Installation Manual
2-11
U V W
Connect power
cord wires to
TB1 and ground
stud.
Green/
Yellow
Black
Blue
Brown
TB1
Figure 2-10 Connecting Power Cord to Powermax900 CE Power Supply
GND
CHOOSING PLUG, POWER CORD AND LINE DISCONNECT BOX
FUSE
Power Cord Plug
The 230V CE Powermax900 kit is shipped with a three-phase power cord and no plug. The
user must obtain a plug that is certified by national or local electrical codes. The plug should be
connected to the power cord by a licensed electrician.
Power Cord - 230V
If the three-phase power cord length needs to be changed, use the table below to choose the proper
gauge size for the appropriate length. Use cords that are certified by national or local codes. The
cord should be installed only by a licensed electrician.
Input
Input
Recommended Power Cord Gauge Size (mm
2
)
Voltage
Current
< 3 m
3 – 7.5 m
7.5 – 15 m
15 – 30 m
30 – 45 m
230 VAC
21 amps
2.5
4
6
10
16