Hand Torch Part Replacement Procedures
4
50
810460
Service Parts and Procedures
SmartSYNC
d.
Make sure that the white wires of the torch lead point up.
e.
Use a 1/2-inch wrench and a 5/8-inch wrench to tighten the gas fitting. Tighten to 6.78 N∙m
(60 lbf∙in). Do not tighten too much. Make sure that the torch body and torch lead stay
aligned.
1
2
1
1
Flat sides of the torch body
2
White wires
5/8 inch
1/2 inch
NOTICE
To prevent damage to the torch, always use 2 wrenches to loosen or tighten the gas fitting.
NOTICE
Do not bend the gas tube. If you bend the gas tube, you will not be able to install the torch body in the
torch handle again because it will not fit correctly.