User manual R3
DLCP
- 15 -
3.2
Application notes
The DLCP has to be placed in an enclosure with enough airflow. Please mount the DLCP with spacers
on a solid surface. All four mounting holes are connected to ground with a 100nF capacitor. Connect
them all to chassis with a metal spacer for optimum EMI performance.
Please use the amp_enable pin to guarantee a pop-free startup and shut down of the connected am-
plifier.
Please use the XLR input balanced, even if the source is unbalanced. For more information how to
benefit of a balanced connection, even with an unbalanced source, please see this document;
http://www.hypex.nl/docs/wiring.pdf
And
Chapter 12 of:
http://www.hypex.nl/docs/NC400_datasheet.pdf