Appendices
8
Appendices
8.1
FAQ – Frequently asked questions
Data Logger
§
If the housing is damaged
: Please contact the customer support and send in the device for maintenance.
§
The cable is damaged
: Please contact the customer support and send in the device for maintenance.
§
The inside humidity increases
:
§
If the humidity inside the device rises, the drying agent is used up. The bags of drying agent (bags of 2g Silica-Gel)
should be replaced. The drying agent can be purchased from your local reseller or from a specialist shop.
§
If the humidity inside the device rises rapidly within a very short time, the hermetic sealing might be damaged.
This can happen due to material expansion caused by big temperature difference. Please replace O-rings and cable
couplings to avoid damage. Please contact the customer support.
HyQuest Solutions GP-Shell – local Software
§
Error message during installation
: No Interface 'Wireless Dongle' found
§
A USB Near Field Radio dongle is required by the software to start. Make sure the USB dongle is connected to your
computer properly and start the software again.
§
Access code
§
All loggers are protected with an access code which consists of four characters.
§
This code is delivered with the loggers and must be entered in GP Shell before a logger can be identified and
accessed by the software.