© 2022 HyQuest Solutions
111
Operation
For iRIS loggers fitted with more than one telemetry module, use AINT1 and AINT2 instead of AINT in order to
change the interval of the according telemetry module. When still using AINT while two telemetry modules
are fitted the value will be set for the first value.For iRIS loggers fitted with more than one telemetry module,
this command will only affect the schedule of the cellular module of which the SIM is fitted.
OUT – Change the state of the digital OUTputs
This command allows the user to control the digital outputs of the device. For this feature to be effective the digital
output must be configured to Remote mode (see section
, Digital Output Modes). Also, the iRIS will only act
on the command if the received command is from one of the phone number in the approved/authorised SMS list (see
section
for configuring these number).
The possible commands are:
Command
Description
OUTx y
Change digital output x to state y.
x = 1 – Digital IO (DIO) terminal.
x = 2 – Digital Out (DO) terminal.
y = On
y = OFF.
The response is in the format (if the senders SMS number is authorised)
<SiteName> (<SerialNumber>)<DateTime>:<MessageN> <State>
Where elements are as follows:
Element
Description
<SiteName>
Site name of the iRIS.
<SerialNumber>
Serial number of the iRIS.
<DateTime>
Time of the message as it is sent using the iRIS local settings.
<MessageN>
Default Message
User Message Index
OUT1
1
OUT2
2