© 2022 HyQuest Solutions
83
Configuration
5. In the
REGISTERS
section select the
S_INT16
data type and click the [
ADD
] button. This will add signed integer data
type to the Registers List. If the type is incorrect entered then click the tick box next to the incorrect data type in the
list, choose the correct type and click the Change button.
6. Repeat previous step 5 times, until there are six S_INT16 data types in the Register List.
7. Click the [
SEND CONFIG
] button to commit this to the iRIS.
8. Click the [
RETRIEVE CONFIG
] button to obtain the dynamically created indices.
9. In HydroTel Client, if not already done so create a logger and site.
10. For the Device Parameters configure the:
a.
Logger RX Buffer Start Address (dxxx)
to be
1010
and the
Size
to be
3
. This is the locations that are written to in
the iRIS from HydroTel.
b.
Logger TX Buffer Start Address (dxxx)
to be
1013
and the
Size
to be
3
. This is the locations that are read from the
iRIS by HydroTel.