Installation
It is very important that the four retaining pins are locked installation to maintain the IP65 rating of the
enclosure.
2.2
Opening / Closing the Housing
The front of the iRIS enclosure is secured by four quarter turn locking pins with Phillips® heads.
§
To Open
: Undo all four locking pins by pressing down with screwdriver and rotate a quarter turn in the anti-clockwise
direction. The pin has a spring, which eject the pin to the open state. The pins are retained in the lid. The front cover
should then be lifted away from the base, note there not any hinges so care should be taken not to place any stress
on the ribbon cable between the base and lid.
§
To Close
: Place the lid on the base, ensuring the ribbon cable does not pinch. In turn, apply pressure to each pin so
that the spring is completely pressed, then turn clockwise a quarter turn until locked.
2.3
I/O Connector
All I/O and power supply terminations are via 5mm (0.2”) pitch screw terminals provided on a 12-way and 10- way
pluggable connector. The I/O connectors are positioned externally on each side of the logger enclosure to allow easy
unplugging of the logger. The function of each I/O termination is shown in the diagrams below.
Figure 3 – Right hand side I/O Connector
* Only available with pro version.
Summary of Contents for iRIS Under Cover
Page 1: ...iRIS Under Cover User Manual ...
Page 13: ... 2022 HyQuest Solutions 13 Installation Figure 2 Mounting Diagram ...
Page 108: ... 2022 HyQuest Solutions 108 Appendices 8 1 Declaration of Conformity ...
Page 115: ... 2022 HyQuest Solutions 115 Appendices ...
Page 117: ...www hyquestsolutions com 2022 HyQuest Solutions 29 06 2022 ...